Bộ nguồn (PSU) đúc phủ LSR: Các thành phần polyphenylsulfone (PPS) kết dính bằng silicone đạt tiêu chuẩn y tế, chịu nhiệt độ cao

This product is a high-performance composite component manufactured using LSR (Liquid Silicone Rubber) overmolding on PSU (Polyphenylsulfone / Polysulfone).

It combines the exceptional high-temperature resistance and dimensional stability of PSU with the flexibility, sealing performance, and biocompatibility of medical-grade liquid silicone rubber.

This product is a high-performance composite component manufactured using LSR (Liquid Silicone Rubber) overmolding on PSU (Polyphenylsulfone / Polysulfone).

It combines the exceptional high-temperature resistance and dimensional stability of PSU with the flexibility, sealing performance, and biocompatibility of medical-grade liquid silicone rubber.

The structure is widely used in medical, laboratory, and high-end fluid control systems where repeated sterilization, chemical resistance, and long-term reliability are required.

Through precision injection overmolding, the LSR layer is permanently bonded to the PSU substrate, forming a stable soft-hard integrated structure that eliminates traditional sealing assemblies.


Key Advantages of LSR Over PSU

Excellent High Temperature Resistance

PSU is a high-performance thermoplastic engineered for extreme thermal environments.

  • Continuous use temperature up to 160°C
  • Excellent dimensional stability under heat
  • Suitable for repeated sterilization cycles

Medical Grade Silicone Performance

The LSR overmold provides biocompatible sealing and flexible interface functionality.

  • ISO 10993 compliant
  • USP Class VI certified material
  • Non-toxic, odorless, and chemically stable
  • Suitable for direct and indirect medical contact

Superior Sterilization Resistance

Designed for demanding medical and laboratory environments.

  • Resistant to autoclave sterilization (121°C–134°C)
  • Compatible with EO and gamma sterilization
  • No cracking, deformation, or yellowing

Excellent Chemical Resistance

PSU combined with LSR provides strong resistance to aggressive media.

  • Resistant to disinfectants and cleaning agents
  • Stable in acidic and alkaline environments
  • Suitable for repeated chemical exposure

Integrated Sealing and Structural Design

LSR overmolding eliminates traditional assembly components.

  • No O-rings or secondary seals required
  • Giảm nguy cơ rò rỉ
  • Improved system reliability and assembly efficiency

Quy trình sản xuất

The product is manufactured using precision overmolding technology:

  1. PSU Injection Molding
    High-performance polysulfone is molded into the structural base.
  2. Chuẩn bị bề mặt
    Surface activation improves bonding performance.
  3. LSR Overmolding
    Liquid silicone rubber is injected onto PSU substrate.
  4. Làm cứng bằng nhiệt
    Silicone is cured to form a permanent bonded interface.
  5. Quality Inspection
    Sealing performance, adhesion strength, and dimensional accuracy are verified.

Thông số kỹ thuật

Mặt hàng Mô tả
Tên sản phẩm LSR Overmolded PSU Component
Base Material PSU (Polysulfone / Polyphenylsulfone)
Overmold Material Liquid Silicone Rubber (LSR)
Quy trình Injection Overmolding
Continuous Temperature Up to 160°C
Sterilization Methods Autoclave, EO, Gamma
Khả năng chống ăn mòn hóa chất High (detergents, disinfectants)
Tính tương thích sinh học ISO 10993 / USP Class VI
Loại kết cấu Rigid PSU + flexible silicone sealing

Ứng dụng

  • Medical sterilization equipment components
  • Surgical and diagnostic device housings
  • Laboratory fluid handling systems
  • Pharmaceutical processing equipment
  • High-temperature fluid control systems
  • Reusable medical device assemblies
  • Precision medical connectors and seals

Các vấn đề kỹ thuật cần lưu ý

Bonding Between LSR and PSU

PSU has high chemical stability and low surface energy, requiring:

  • Plasma surface treatment
  • Specialized medical-grade primer systems
  • Controlled molding temperature for adhesion stability

Thermal Compatibility

Both materials are selected for high-temperature environments:

  • PSU provides structural rigidity at elevated temperatures
  • LSR maintains elasticity after repeated sterilization cycles

Sterilization Performance Design

The system is optimized for:

  • Repeated autoclave cycles
  • Long-term chemical exposure
  • Dimensional stability after thermal cycling

Các câu hỏi thường gặp

Why choose PSU instead of PC or PA?

PSU offers significantly higher heat resistance and better long-term stability under sterilization conditions.

Is LSR suitable for medical applications?

Yes, medical-grade LSR is widely used in ISO 10993 and USP Class VI certified applications.

Can this product withstand repeated sterilization?

Yes, it is designed for repeated autoclave, EO, and gamma sterilization processes.

Có thể tùy chỉnh không?

Yes, PSU grade, silicone hardness, structure design, and sealing geometry can be customized.

Đánh giá

Hiện chưa có đánh giá nào.

Hãy là người đầu tiên đánh giá “LSR Overmolded PSU Medical Grade High Temperature Resistant Silicone Bonded Polyphenylsulfone Components”

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *

CUSTOM SILICONE PROJECT

Need a Custom Silicone Solution?

Send us your drawings, dimensions, material requirements, estimated quantity and application details. Our team will review your project and provide a suitable manufacturing solution and quotation.